Language
Product case

Remote Assistance, Spare Parts Service, Technical Support
Reason for ECUT 1620 Light Alarm
2020-4-3 14:18:36
Back to list

Two reasons for Light No. 10 Alarm

3-1.png

  Sheet paper exceed

1  Check if the mechanical angle and electrical angle are synchronous


  18-11.png179.png

                                                                         

 2  Check photoelectricity

If there is no sheet under the photoelectricity, the green light will on; if there is sheet under the photoelectricity, the green light and the red light will be on together.

未标题-5.png2-1.png

  Check if the paper feeding time is too fast. Under normal circumstances, the paper edge reaches about 237 degrees under photoelectricity.。  

18-03.png  


  Paper Dropped Off

18-A1.png

Reason for paper dropped off  

 1   Paper arrived the front gauge, but gripper doesn't hold the paper, so the alarm happens during operation

 2   When gripper grabs the paper, the photoelectric detection for length of the paper and for front gauge will give an alarm , aslo would adjust the photoelectric sensitivity of the front gauge (when reaches the lowest point, the photoelectric detection of the front gauge cannot light on the paper) 

18-C2.png




Prev:ECUT 1620 NO. 16 LIGHT ALARM

 